青青草原综合网-青青草原综合久久大伊人精品-青青草原在线新免费-青青草原影视-青青草原伊人网-青青草原伊人

上海沃華產(chǎn)品技術(shù)服務(wù)有限公司,為您提供一站式的注冊(cè)服務(wù)!全國(guó)統(tǒng)一免費(fèi)服務(wù)熱線(xiàn):400-016-1080   021-51088618 Chinese/English
服務(wù)范圍
美國(guó)FDA質(zhì)量管理體系QSR820咨詢(xún)返回首頁(yè)

QSR 820 法規(guī)從1996年發(fā)布以來(lái),歷史上進(jìn)行了6次小型的技術(shù)修改。如下

 

Technical Amendment
Federal Register Citation

65 FR 17136
(31-Mar-2000)

Change removed paragraphs (e) and (f) from 820.1 Scope.

PART 820—QUALITY SYSTEM REGULATION
7. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 351, 352, 360, 360c, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.
8. Amend § 820.1 by removing paragraphs (e) and (f).


65 FR 66636
(07-Nov-2000)

Change restored paragraph (e) to 820.1 Scope.

 

PART 820—QUALITY SYSTEM REGULATION
5. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.
6. Section 820.1 is amended by adding paragraph (e) to read as follows:
§ 820.1 Scope.
* * * * *
(e) Exemptions or variances. (1) Any person who wishes to petition for an exemption or variance from any device quality system requirement is subject to the requirements of section 520(f)(2) of the act. Petitions for an exemption or variance shall be submitted according to the procedures set forth in § 10.30 of this chapter, the FDA’s administrative procedures. Guidance is available from the Center for Devices and Radiological Health, Division of Small Manufacturers Assistance (HFZ–220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1–800–638–2041 or 1–301–443–6597, FAX 301–443–8818.

(2) FDA may initiate and grant a variance from any device quality system requirement when the agency determines that such variance is in the best interest of the public health. Such variance will remain in effect only so long as there remains a public health need for the device and the device would not likely be made sufficiently available without the variance.


69 FR 11313
(10-Mar-2004)

Change removed reference to 21 CFR 804, which was deleted from the CFR.

 

PART 820—QUALITY SYSTEM REGULATION
14. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l 371, 374, 381, 383.
15. Section 820.198(d) is revised to read as follows
§ 820.198 Complaint files.
* * * * *
(d) Any complaint that represents an event which must be reported to FDA under part 803 of this chapter shall be promptly reviewed, evaluated, and investigated by a designated individual(s) and shall be maintained in a separate portion of the complaint files or otherwise clearly identified. In addition to the information required by § 820.198(e), records of investigation under this paragraph shall include a determination of:
(1) Whether the device failed to meet specifications;
(2) Whether the device was being used for treatment or diagnosis; and
(3) The relationship, if any, of the device to the reported incident or adverse event.
* * * * *
16. Section 820.200(c) is revised to read as follows:
§ 820.200 Servicing.
* * * * *

c) Each manufacturer who receives a service report that represents an event which must be reported to FDA under part 803 of this chapter shall automatically consider the report a complaint and shall process it in accordance with the requirements of § 820.198.


69 FR 29829
(25-May-2004)

Changed to specifically note applicability of 21

CFR 820 to tissue products, under newly released 21 CFR 1271.

Also, the Quality System regulation contains a typographic error: it has a date of 2005, but 2004 is the correct date.

 

PART 820—QUALITY SYSTEM REGULATION
6. The authority citation for 21 CFR part 820 is revised to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383; 42 U.S.C. 216, 262, 263a, 264.
7. Section 820.1 is amended by adding two sentences to the end of paragraph (a)(1), and by revising paragraph (b) to read as follows:
§ 820.1 Scope.
(a) Applicability. (1) * * *
Manufacturers of human cells, tissues, and cellular and tissue-based products (HCT/Ps), as defined in § 1271.3(d) of this chapter, that are medical devices (subject to premarket review or notification, or exempt from notification, under an application submitted under the device provisions of the act or under a biological product license application under section 351 of the Public Health Service Act) are subject to this part and are also subject to the donor-eligibility procedures set forth in part 1271 subpart C of this chapter and applicable current good tissue practice procedures in part 1271 subpart D of this chapter. In the event of a conflict between applicable regulations in part 1271 and in other parts of this chapter, the regulation specifically applicable to the device in question shall supersede the more general.
* * * * *
(b) The quality system regulation in this part supplements regulations in other parts of this chapter except where explicitly stated otherwise. In the event of a conflict between applicable regulations in this part and in other parts of this chapter, the regulations specifically applicable to the device in question shall supersede any other generally applicable requirements.


71 FR 16228
(31-Mar-2006)

Change removed reference to 21 CFR 804, which was deleted from the CFR.

PART 820—QUALITY SYSTEM REGULATION
3. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.

4. Amend paragraph (a)(3) of § 820.198 by removing ‘‘or 804’’.


72 FR 17397
(09-Apr-2007)

Change updated title, address, and phone numbers for DSMICA.

PART 820—QUALITY SYSTEM REGULATION

6. FDA is revising Sec.  820.1(e) and replacing “Division of Small Manufacturers Assistance (HFZ-220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1-800-638-2041 or 1-301-443-6597, FAX 301-443-8818” with “Division of Small Manufacturers, International and Consumer Assistance (HFZ-220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1-800-638-2041 or 240-276-3150, FAX 240-276-3151.”

企業(yè)介紹 | 法律聲明 | 網(wǎng)站地圖 | 認(rèn)證查詢(xún) | 資料下載 | 在線(xiàn)留言 | 聯(lián)系方式
上海沃華產(chǎn)品技術(shù)服務(wù)有限公司 Copyright 2025 y6yy.cn, 版權(quán)所有 滬ICP備16037738號(hào)-1
電話(huà):021-51088618;400-016-1080 地址:上海市長(zhǎng)寧區(qū)天山路641號(hào)慧谷白貓科技園1號(hào)樓701室
友情鏈接: CE認(rèn)證 | BIM咨詢(xún) | 深圳注冊(cè)公司

滬公網(wǎng)安備 31010502002363號(hào)


国产成人无码免费一区二区三区 | 人妻被粗大猛进猛出69视频 | 丰满少妇中文字幕 | 丰满美女无遮挡毛毛A片 | 国产真实乱了老女人视频 | 中文字幕一区二区无码成人 | 有没有免费的毛片 | 一级毛片久久久久久 | 四虎影视永久在线精品免费 | 国产精品无码午夜福利免费看 | 婷婷五月五月婷婷 | 少女视频哔哩哔哩免费播放在线观看 | 亚洲AV永久无无码精品一区二区三区 | 拍国产真实乱人偷精品 | 亚洲AV无码乱码在线观看性色 | 亚洲乱码一区二区三区 | 西西444WWW无码短视频 | 国产又粗又猛又爽又黄无码的视频 | 日韩精品视频一区二区三区四区 | 国产美女裸体永久免费 | 日韩无码黄色电影 | 久久精品—区二区三区舞蹈 | 国精产品一区二区免费 | 人妻熟妇乱子伦精品无码专区毛片 | 成年人黄色免费网 | 中文字幕av久久爽一区 | 91在线无码观看蜜桃 | 亚洲AV无码乱码国产精品牛牛 | 波多野结衣高潮到受不了 | 久久久久99精品成人网站 | 中文无码AV一区二区三区 | 美女自慰喷水网站 | 亚洲精品国产精品国 | 久久精品欧美一区二区三区不卡 | 91福利在线观看 | 免费 无码 AV在线观看 | 91精品国产综合久久喷水蘑菇 | 国产Ⅹ丈XX推油按摩BBBB | 精品亚洲乱码一区二区 | 人体艺术私拍丰满亚洲一区二区三区 | 少妇与性猛交ⅩXXX乱大交麻豆 |